845-454-8171 Menu

Moisture Purge Systems

By: Tom Frankel
Post Date: November 23rd 2016

Post Tags:

SSI offers two types of moisture purge systems:

  1. The most common type of purge is an airlift.   We make these out of small diameter pipe, starting with a dip tube into a submerged manifold, and rising to just above the water surface. A butterfly valve can be opened to drain the piping system.
  2. The other type is a continuous purge, which is a diffuser installed at the invert of the submerged pipe.  It can be a fine or coarse bubble diffuser.   This kind of purge is often used on retrievable grids or where an an airlift purge valve is inaccessible.

 

Airlift Purge - Bottom

Airlift Purge – Bottom

 

 

 

Airlift Purge - Top (left side of tank).

Airlift Purge – Top (left side of tank).

 

 

 

Continuous Purge on Manifold Invert.

Continuous Purge on Manifold Invert.

 

Top of Purge with Valve

Top of Purge with Valve